DNP3 SLAVE DRIVER

For example if the DNP3 Master send a pulse on with count of 10, on time 10, off time 10 to Configurable Keep Alive Timer for use in unsolicited mode. Disable 0 - The device is not started or polled Enable Unsolicited Messages Enable the transmission of unsolicited messages for Slave. Pulse On - The point is turned on for on time, then turned off for off time. Most communication is unsolicited, but also polls for event data. DNP3 Slave can act as server or as client. Standby 2 - The device is started, but the polling schedule is suspended.
Uploader: Jukasa
Date Added: 28 April 2015
File Size: 19.37 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 2582
Price: Free* [*Free Regsitration Required]





Events Request application confirmation when sending event data. Event data older than Event lifetime are discarded by the slave. Put all devices attached to this port online at startup.

Writing a 2 to A read request to " Writing a 1 value to. Station Address of Slave.

DNP3 OPC Server Configuration Guide

Unsolicited data buffer time, a value of zero means that events are sent immediately. Set to 0 to disable this feature. Master device Application Layer Initial poll message. WriteOnly" of that slave. Class 0 poll are issued at a very slow rate to keep DNP3 Master database is up to date.

The meaning of the result code are: The DNP3 master can be scheduled to perform regular polling for class 0, 1, 2 or 3 data.

DNP3 OPC Server Configuration Guide

DO suffix in object name when writing to the broadcast device. Perform a read after operating the output. SO suffix in object name. Enable Level 3 commands, this option should only be enable if the Dn;3 support the following level 3 command: Maximum time to wait for an application confirmation or fragment.

To find out what type of data is available, connect to IOServer, using the built in OPC Server explorer, add a group then add item to see the available data types.

DNP Master/Slave Communication Module - ProSoft Technology Inc

Most RTU will statically assign a default class to each event object. Read after Operate Perform a read after operating the output.

The Device Polling schedule can be paused by writing a value of 2 to the Device. Time offset between clocks on Slave station and Master station. Not recommended dmp3 it is very inefficient when the number of points is high and changes are infrequent. Enable tag of the device.

Data Link Confirmation mode is set to Never. Master Devices will accept both time-tagged and non-time-tagged for all event data. IOServer running on a Pentium 4, 2. SO will pulse This is used to limit the amount of data that a level 2 slave may return per poll.

If the slave reports 2.

Leave this field blank if restoration of timestamp is not necessary, otherwise specify sllave different filename for each device.

After the write, the result code of the operation is available in The result code of the response will be reported in Log Link Layer messages to log file. Stop that device immediately and put that device offline.